SkillsLib.ai

Daylighting Performance Analyzer

Calculate illuminance distribution, daylight factors, and seasonal daylighting performance for ar...

3.8(32 reviews)
100+ downloads
Updated Sep 2026
Verified SafeSecurity VerifiedThis skill was analyzed by our AI security scanner for harmful content including data exfiltration, system manipulation, credential theft, and prompt injection. No threats were detected.

What You Can Do

You can rapidly assess daylighting performance by inputting space geometry, glazing specifications, and site climate data. The skill calculates predicted illuminance levels, daylight factors, seasonal variations, and identifies underlit zones requiring supplemental lighting. You'll synthesize complex interdependencies between window-to-wall ratios, orientation, shading devices, interior reflectances, and latitude to produce actionable design guidance for early-stage validation and compliance documentation.

Features

Illuminance distribution mapping

Calculates predicted light levels across floor plans and identifies dark zones

Daylight factor (DF) analysis

Computes DF compliance for residential and institutional projects against building standards

Seasonal performance modeling

Evaluates equinox and solstice conditions to show annual daylighting variation

Shading device optimization

Tests louver spacing, depth, and tilt angle effectiveness across orientations

Obstruction impact assessment

Analyzes performance in north-facing, east-facing, and obstructed site conditions

Interior reflectance modeling

Quantifies ceiling, wall, and finish reflectance effects on light distribution

Multi-standard compliance checking

Validates against WELL v2, IES LM-83, and Passivhaus criteria

Glazing comparison reports

Side-by-side analysis of window-to-wall ratios and material options

Example Output

Example 1: Office Floorplan Daylight Factor Analysis

  • South-facing perimeter: DF 3.2% (exceeds 2% threshold)
  • Core zones (5m from windows): DF 0.8% (supplemental lighting needed)
  • Recommendation: Add 1.2m light shelves on south facade to redirect light 6m deeper

Example 2: Seasonal Illuminance Comparison

  • Winter solstice (Dec 21): 180 lux at 3m from window (below 300 lux task threshold)
  • Equinox (Sept 21): 480 lux at 3m from window (exceeds 300 lux)
  • Summer solstice (June 21): 720 lux (requires 70% external shading to prevent glare)

Example 3: Glazing Option Comparison

  • Option A (40% WWR, standard glazing): Average DF 1.8%, 65% of space meets target
  • Option B (50% WWR, low-E glazing): Average DF 2.1%, 78% of space meets target
  • Recommendation: Proceed with Option B; reduces supplemental lighting energy by ~18%

What's Included

  • SKILL.md instruction file with skill overview and usage parameters:
  • Space Geometry Template: Input worksheet for room dimensions, window placement, and obstruction details
  • Glazing Specification Checklist: Performance data input form (transmittance, U-value, solar heat gain coefficient)
  • Climate Data Framework: Latitude, longitude, and seasonal sun angle reference tables
  • Performance Reporting Worksheet: Illuminance mapping grid, daylight factor calculation matrix, and compliance summary checklist

Who It's For

  • Architectural lighting designers — Validating daylighting strategies and preparing technical compliance documentation
  • Sustainable design specialists — Ensuring WELL, Passivhaus, and net-zero energy performance targets
  • Schematic/design phase architects — Comparing glazing options and aperture sizing decisions early in projects
  • Code compliance consultants — Demonstrating adherence to IES daylight metrics and local building standards
  • Passive house designers — Optimizing window placement and shading to maximize passive heating while managing glare

Best For

  • Calculating daylight factor (DF) compliance across residential and institutional floorplans
  • Comparing window-to-wall ratios, glazing materials, and orientation options quantitatively
  • Assessing shading device effectiveness (louver depth, spacing, tilt angles) across seasons
  • Identifying underlit zones that require hybrid lighting strategies or supplemental electric lighting
  • Preparing design narratives and compliance documentation for stakeholder presentations and code review

You might also like

Environmental Noise Impact Assessment Framework
$40
Environmental Noise Impact Assessment Framework

You can generate complete environmental noise impact assessments (NIAs) that characterize baseline conditions, identify noise sources, map sensitive receptors, interpret predictive modeling outputs, and evaluate compliance against EPA guidelines, OSHA standards, and local ordinances. The framework guides you through cumulative impact analysis and helps you develop technically defensible mitigation recommendations that balance regulatory requirements with project feasibility and budget constraints.

Auditorium Acoustic Performance Analyzer
$35
Auditorium Acoustic Performance Analyzer

You can systematically evaluate auditorium acoustic performance by inputting measured data (impulse response, RT60, speech intelligibility metrics) or simulation results, then receive detailed analysis identifying specific frequency-dependent problems, quantified deviations from ISO 3382 and AES standards, and prioritized remediation strategies. Claude cross-references your data against performance benchmarks and generates technical justifications suitable for architect presentations, client reports, and construction specifications.

Facade Thermal Bridge Analysis & Mitigation
$35
Facade Thermal Bridge Analysis & Mitigation

You can map thermal bridge locations in building envelopes, quantify their effect on overall facade thermal performance (U-value degradation), assess condensation formation risk through surface temperature analysis, and develop detailed mitigation strategies aligned with energy codes and construction feasibility. Claude helps you bridge the gap between idealized thermal calculations and actual building performance by integrating linear and point thermal transmittance into energy models.

Structural Glass Load Analysis & Documentation
$45
Structural Glass Load Analysis & Documentation

You can input architectural parameters, environmental data, and code requirements to automatically calculate simultaneous loads on glass assemblies, determine minimum glass thickness and support specifications, and generate glazing schedules and stress reports. This eliminates manual load case combinations and identifies design conflicts before fabrication, ensuring compliance with building codes and reducing engineering rework.

Room Acoustic Analysis and Treatment Design
$40
Building3.9(31)
Room Acoustic Analysis and Treatment Design

You can systematically evaluate room acoustic conditions by calculating reverberation times (RT60) using Sabine formulas, identifying problem frequencies and room modes, analyzing absorption material performance across frequency ranges, and generating detailed acoustic treatment specifications with scientific justification. The skill produces professional-grade acoustic solutions tailored to your space constraints, budget, and performance targets while maintaining compliance with standards like ISO 3382 and ASTM C423.

Daylighting Performance Analysis & Optimization
$45
Daylighting Performance Analysis & Optimization

You can systematically evaluate natural light performance in building spaces by calculating daylight availability, assessing visual comfort metrics, and managing solar thermal loads. The skill guides you through measurable daylighting performance indicators—daylight factor, illuminance levels, uniformity ratios—and translates them into actionable glazing recommendations for architects and engineers that comply with LEED, WELL Building Standard, and European building codes.

Shopify Liquid Template Development Expert
$40
Shopify Liquid Template Development Expert

You'll write production-ready Shopify Liquid templates that follow best practices, debug complex template issues, and optimize for performance. Whether you're building custom product pages, creating dynamic collection templates, or fixing rendering bugs, this skill provides expert guidance on Liquid syntax, theme architecture, and performance optimization.

Smoke Control System Design Analyzer
$50
Smoke Control System Design Analyzer

You can rapidly evaluate smoke control system designs by calculating required pressurization differentials, airflow requirements, and fan capacity specifications. The skill validates compliance against NFPA 92, IBC Chapter 9, and local amendments while analyzing integration points with HVAC and fire alarm systems. It identifies design gaps, suggests optimization opportunities, and generates technical documentation to support the full design lifecycle from concept through commissioning.

$40.00